Resultados 1 - 20 de 14.115
Filtrar
1.
Environ Sci Technol ; 58(15): 6772-6780, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38577774

RESUMO

The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program. The median CV over all rounds was 32%. Much higher variabilities were observed for hydrophilic compound concentrations in the sorbent: 50% for the untransformed data and a factor of 1.6 after log transformation. Limiting the data to the best performing laboratories did not result in less variability. Data quality for hydrophilic compounds was only weakly related to the use of structurally identical internal standards and was unrelated to the choice of extraction solvent and extraction time. Standard deviations of the aqueous concentration estimates for hydrophobic compound sampling by the best performing laboratories were 0.21 log units for silicone and 0.27 log units for LDPE (factors of 1.6 to 1.9). The implications are that proficiency testing programs may give more realistic estimates of uncertainties in chemical analysis than within-laboratory quality control programs and that these high uncertainties should be taken into account in environmental assessments.


Assuntos
Polietileno , Poluentes Químicos da Água , Polietileno/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Compostos Orgânicos , Silicones
2.
Eur Radiol Exp ; 8(1): 40, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38565836

RESUMO

BACKGROUND: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. METHODS: The study involved 42 Sprague-Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. RESULTS: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. CONCLUSIONS: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. RELEVANCE STATEMENT: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. KEY POINTS: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis.


Assuntos
Hipertermia Induzida , Nanopartículas Metálicas , Ratos , Animais , Ouro , Silicones , Estudos de Viabilidade , Ratos Sprague-Dawley , Esôfago , Stents
3.
J Adhes Dent ; 26(1): 93-102, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602286

RESUMO

PURPOSE: To investigate the influence of contamination and different cleaning methods on resin bonding to cobalt-chro- mium (CoCr) alloy disks. MATERIALS AND METHODS: A total of 160 CoCr disks were divided into 3 groups. The first group (N = 64) was air abraded with alumina particles and contaminated with a silicone disclosing agent and saliva; the second group (N = 64) was air abraded but not contaminated; the third group (N = 32) was neither air abraded nor contaminated. The first two groups were di- vided into 4 subgroups (N = 16) according to the cleaning method: ultrasonic bath in 99% isopropanol, use of a cleaning suspension of zirconium oxide particles, use of a cleaning suspension based on 10-MDP salt, and treatment with atmo- spheric plasma. The third group was divided into 2 subgroups (N = 16): treatment with atmospheric plasma and no treat- ment. All CoCr specimens were bonded to plexiglas tubes filled with a bonding resin that contained phosphate monomer. Tensile bond strength (TBS) was examined by tensile testing after 3 and 150 days of water storage plus 37,500 thermal cy- cles (N = 8). RESULTS: After contamination, TBS was significantly reduced after 150 days of water storage. Groups without air abrasion showed initially low TBS and debonded spontaneously after 150 days of water storage. CONCLUSION: None of the cleaning methods was able to remove saliva and silicone disclosing agent on CoCr-alloy sur- faces. Surface activation by plasma treatment has no long-term effect on the bond strength.


Assuntos
Resinas Compostas , Colagem Dentária , Cimentos de Resina , Ligas , Abrasão Dental por Ar , Propriedades de Superfície , Água , Resistência à Tração , Silicones , Teste de Materiais , Zircônio , Análise do Estresse Dentário
4.
Top Curr Chem (Cham) ; 382(2): 11, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589726

RESUMO

Silicone surfactants have garnered significant research attention owing to their superior properties, such as wettability, ductility, and permeability. Small-molecular silicone surfactants with simple molecular structures outperform polymeric silicone surfactants in terms of surface activity, emulsification, wetting, foaming, and other areas. Moreover, silicone surfactants with small molecules exhibit a diverse and rich molecular structure. This review discusses various synthetic routes for the synthesis of different classes of surfactants, including single-chain, "umbrella" structure, double chain, bolaform, Gemini, and stimulus-responsive surfactants. The fundamental surface/interface properties of the synthesized surfactants are also highlighted. Additionally, these surfactants have demonstrated enormous potential in agricultural synergism, drug delivery, mineral flotation, enhanced oil recovery, separation, and extraction, and foam fire-fighting.


Assuntos
Silicones , Tensoativos , Tensoativos/química , Propriedades de Superfície , Estrutura Molecular
5.
Environ Sci Technol ; 58(15): 6499-6508, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38572580

RESUMO

A social housing estate in Denmark was designated for demolition due to exceedance of guidance values for polychlorinated biphenyls (PCBs) in indoor air. Here, we deployed precleaned silicone wristbands (n = 46) among demolition workers of these contaminated buildings during single workdays while conducting various work tasks. We established a method to analyze all 209 PCBs in wristbands to identify prominent congeners of exposure and evaluate differences between tasks. Wristbands were extracted using microwave-assisted extraction and then concentrated for gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. Twenty-nine chromatographic peaks representing 37 congeners were detected in every wristband, and tetra-CBs were the dominant homologue group. PCB-66, -44, and -70 were the most abundant congeners measured in worker wristbands, none of which are included within the typical seven indicator or WHO 12 PCBs. Workers who cut PCB-containing sealants had wristbands with the highest PCB concentrations (geometric mean ∑209PCBs = 1963 ng/g wristband), which were followed by those handling concrete elements on the building roof. Additionally, wristbands captured a broader range of PCBs than has been previously measured in air and serum samples. Taken together, our results highlight the importance of total congener analysis in assessing current PCB exposure in demolition work and the utility of wristbands for assessing these exposures.


Assuntos
Bifenilos Policlorados , Humanos , Bifenilos Policlorados/análise , Monitoramento Ambiental , Espectrometria de Massas em Tandem , Silicones
6.
Front Immunol ; 15: 1342895, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38566997

RESUMO

Excessive fibrous capsule formation around silicone mammary implants (SMI) involves immune reactions to silicone. Capsular fibrosis, a common SMI complication linked to host responses, worsens with specific implant topographies. Our study with 10 patients investigated intra- and inter-individually, reduced surface roughness effects on disease progression, wound responses, chronic inflammation, and capsular composition. The results illuminate the significant impact of surface roughness on acute inflammatory responses, fibrinogen accumulation, and the subsequent fibrotic cascade. The reduction of surface roughness to an average roughness of 4 µm emerges as a promising approach for mitigating detrimental immune reactions, promoting healthy wound healing, and curbing excessive fibrosis. The identified proteins adhering to rougher surfaces shed light on potential mediators of pro-inflammatory and pro-fibrotic processes, further emphasizing the need for meticulous consideration of surface design. The composition of the implant capsule and the discovery of intracapsular HSP60 expression highlight the intricate web of stress responses and immune activation that can impact long-term tissue outcomes.


Assuntos
Inflamação , Próteses e Implantes , Humanos , Silicones , Fibrose , Cicatrização
7.
Sci Adv ; 10(14): eadk5949, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578991

RESUMO

The transplantation of engineered cells that secrete therapeutic proteins presents a promising method for addressing a range of chronic diseases. However, hydrogels used to encase and protect non-autologous cells from immune rejection often suffer from poor mechanical properties, insufficient oxygenation, and fibrotic encapsulation. Here, we introduce a composite encapsulation system comprising an oxygen-permeable silicone cryogel skeleton, a hydrogel matrix, and a fibrosis-resistant polymer coating. Cryogel skeletons enhance the fracture toughness of conventional alginate hydrogels by 23-fold and oxygen diffusion by 2.8-fold, effectively mitigating both implant fracture and hypoxia of encapsulated cells. Composite implants containing xenogeneic cells engineered to secrete erythropoietin significantly outperform unsupported alginate implants in therapeutic delivery over 8 weeks in immunocompetent mice. By improving mechanical resiliency and sustaining denser cell populations, silicone cryogel skeletons enable more durable and miniaturized therapeutic implants.


Assuntos
Criogéis , Hidrogéis , Camundongos , Animais , Silicones , Alginatos , Oxigênio , Esqueleto , Sobrevivência Celular
8.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(2): 208-210, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38442941

RESUMO

Transradial approach is the classical access for coronary angiography and percutaneous coronary intervention (PCI). With the increase in the number of interventional procedures, some disadvantages of the transradial approach have also been found, it is easy to lead to various complications, such as radial artery occlusion, radial nerve injury, and puncture difficulties after radial artery spasm. Therefore, some experts put forward the approach of distal radial artery approach for interventional therapy, which has the advantages of convenient positioning, easy postoperative hemostasis, less damage to the proximal radial artery and improving patients' comfort. However, there is no special distal radial artery hemostat in clinic, which limits the development of this approach to a certain extent. Therefore, based on the principles of anatomy and physics, cardiovascular physician at Jiading District District Central Hospital in Shanghai designed and invented a distal radial artery hemostatic device, which is convenient for clinical hemostasis of distal radial artery puncture, and obtained the National Utility Model Patent (patent number: ZL 2021 2 2097829.6). The hemostatic device consists of a glove body with a silicone gasket protruding towards the skin on the inner surface and a binding component. The patient's hand is inserted into the glove body, and after being fixed by the restraint component, the silicone gasket can effectively compress the location of the radial artery puncture point, and play a good hemostatic effect with less pressure, avoid the common complications of proximal radial artery hemostatic, and reduce the discomfort of the patient. Has good application value.


Assuntos
Hemostáticos , Intervenção Coronária Percutânea , Humanos , Artéria Radial , China , Silicones
9.
J Appl Oral Sci ; 32: e20230348, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537029

RESUMO

BACKGROUND: Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain. OBJECTIVE: This study evaluated the impact of repositioning guides' color and usage on tooth color measurement using a clinical spectrophotometer. METHODOLOGY: In total, 18 volunteers participated in this study, in which the color of their upper left central incisor and upper left canine was measured with or without repositioning guides (control). The guides were made from pink, blue, or translucent silicone, as well as an acetate-based bleaching tray. Tooth color was measured in triplicates using a clinical spectrophotometer based on the CIELAB system. The standard deviations of these readings were used to estimate reproducibility, and color differences (ΔE00) between the measurements with guides and the control were calculated. RESULTS: Repositioning guides had a minimal effect on L* values and no effect on b* values. The use of pink silicone increased a* values, whereas blue or translucent silicone reduced them. Irrespective of the evaluated tooth, the lowest ΔE00 values were observed for the translucent silicone and bleaching tray. The usage of guides only affected data variability for the L* color coordinate. CONCLUSION: Using repositioning guides can significantly impact the precision of tooth color measurement with a clinical spectrophotometer.


Assuntos
Incisivo , Clareamento Dental , Humanos , Cor , Reprodutibilidade dos Testes , Espectrofotometria , Silicones
10.
Med Image Anal ; 94: 103152, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531210

RESUMO

Today, fitting bespoke hearing aids involves injecting silicone into patients' ears to produce ear canal molds. These are subsequently 3D scanned to create digital ear canal impressions. However, before digital impressions can be used they require a substantial amount of effort in manual 3D editing. In this article, we present computational methods to pre-process ear canal impressions. The aim is to create automation tools to assist the hearing aid design, manufacturing and fitting processes as well as normalizing anatomical data to assist the study of the outer ear canal's morphology. The methods include classifying the handedness of the impression into left and right ear types, orienting the geometries onto the same coordinate system sense, and removing extraneous artifacts introduced by the silicone mold. We investigate the use of convolutional neural networks for performing these semantic tasks and evaluate their accuracy using a dataset of 3000 ear canal impressions. The neural networks proved highly effective at performing these tasks with 95.8% adjusted accuracy in classification, 92.3% within 20° angular error in registration and 93.4% intersection over union in segmentation.


Assuntos
Meato Acústico Externo , Auxiliares de Audição , Humanos , Meato Acústico Externo/anatomia & histologia , Silicones , Redes Neurais de Computação
11.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542137

RESUMO

Breast cancer is the most common cancer in women globally, often necessitating mastectomy and subsequent breast reconstruction. Silicone mammary implants (SMIs) play a pivotal role in breast reconstruction, yet their interaction with the host immune system and microbiome remains poorly understood. This study investigates the impact of SMI surface topography on host antimicrobial responses, wound proteome dynamics, and microbial colonization. Biological samples were collected from ten human patients undergoing breast reconstruction with SMIs. Mass spectrometry profiles were analyzed for acute and chronic wound proteomes, revealing a nuanced interplay between topography and antimicrobial response proteins. 16S rRNA sequencing assessed microbiome dynamics, unveiling topography-specific variations in microbial composition. Surface topography alterations influenced wound proteome composition. Microbiome analysis revealed heightened diversity around rougher SMIs, emphasizing topography-dependent microbial invasion. In vitro experiments confirmed staphylococcal adhesion, growth, and biofilm formation on SMI surfaces, with increased texture correlating positively with bacterial colonization. This comprehensive investigation highlights the intricate interplay between SMI topography, wound proteome dynamics, and microbial transmission. The findings contribute to understanding host-microbe interactions on SMI surfaces, essential for optimizing clinical applications and minimizing complications in breast reconstruction.


Assuntos
Anti-Infecciosos , Implantes de Mama , Neoplasias da Mama , Humanos , Feminino , Silicones , Implantes de Mama/efeitos adversos , Neoplasias da Mama/cirurgia , Proteoma , RNA Ribossômico 16S/genética , Mastectomia , Fibrose
12.
Clin Oral Investig ; 28(4): 233, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556612

RESUMO

OBJECTIVES: Reconstruction of a three-dimensional jaw position determined by a bite recording is an important aspect of prosthetic therapy. Different materials are used for this purpose. In the dental technical workflow, recordings are used to mount a lower jaw cast in a patient-like spatial position relative to the upper jaw cast. We evaluated the accuracy of positioning under the influence of different jaw positions and materials. MATERIALS AND METHODS: In an experimental setup, comprising an articulator, a pair of metal casts, and an optoelectronic measurement system, the spatial position of the incisal point and two condylar points were measured. To evaluate the accuracy of repeated repositioning of casts in the technical workflow, 324 measurements were taken from 108 recordings, consisting of silicone bite-stops made of addition curing silicone with 95 shore hardness, acrylic wafers, and wax recordings. The recordings were obtained in four jaw relations differing in vertical and protrusive components. RESULTS: Of the three materials/material combinations examined, silicone showed the most consistent results across all measurements, followed by the acrylic wafer system, and then wax recordings. Generally, recordings with smaller gaps between the jaws and no protrusive components showed greater deviations compared to jaw positions with greater protrusion and higher vertical dimensions. CONCLUSIONS AND CLINICAL RELEVANCE: To achieve reliable model mounting with high accuracy, recordings should include the use of a frontal jig and four small recording platelets made of silicone, especially if only a slight elevation of the vertical dimension is needed.


Assuntos
Articuladores Dentários , Mandíbula , Humanos , Registro da Relação Maxilomandibular/métodos , Dimensão Vertical , Silicones
13.
Sensors (Basel) ; 24(5)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38475217

RESUMO

Age-related vessel deterioration leads to changes in the structure and function of the heart and blood vessels, notably stiffening of vessel walls, increasing the risk of developing cardiovascular disease (CVD), which accounts for 17.9 million global deaths annually. This study describes the fabrication of custom-made silicon vessels with varying mechanical properties (arterial stiffness). The primary objective of this study was to explore how changes in silicone formulations influenced vessel properties and their correlation with features extracted from signals obtained from photoplethysmography (PPG) reflectance sensors in an in vitro setting. Through alterations in the silicone formulations, it was found that it is possible to create elastomers exhibiting an elasticity range of 0.2 MPa to 1.22 MPa. It was observed that altering vessel elasticity significantly impacted PPG signal morphology, particularly reducing amplitude with increasing vessel stiffness (p < 0.001). A p-value of 5.176 × 10-15 and 1.831 × 10-14 was reported in the red and infrared signals, respectively. It has been concluded in this study that a femoral artery can be recreated using the silicone material, with the addition of a softener to achieve the required mechanical properties. This research lays the foundation for future studies to replicate healthy and unhealthy vascular systems. Additional pathologies can be introduced by carefully adjusting the elastomer materials or incorporating geometrical features consistent with various CVDs.


Assuntos
Doenças Cardiovasculares , Rigidez Vascular , Humanos , Fotopletismografia , Silicones , Artérias , Elastômeros
14.
Int J Prosthodont ; 37(7): 127-131, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498864

RESUMO

PURPOSE: To evaluate and compare the fracture resistance and elastic modulus of 3D-printed post and core systems and fiber posts and composite cores. MATERIALS AND METHODS: Endodontic treatment was performed on 30 mandibular premolars, and post space preparation was performed. The teeth were then randomly divided into two groups (n = 15 per group): the 3D-printed (3DP) group and the fiber post and composite core (FPC) group. In the FPC group, fiber posts (Cytec Blanco 43.604, Hahnenkratt) were bonded with resin cement (RelyX U200, 3M), and the composite core dimension was standardized with a silicone index. In the 3DP group, the impression of the post space for each specimen was taken with pattern resin (Pattern Resin, GC America), and the coronal core was produced with the same silicone index. The impressions of the posts and cores were scanned, and then the custom post and core structures were fabricated from permanent crown resin material (Permanent Crown Resin, Formlabs) with a 3D printer (Form3B, Formlabs). Specimens were subjected to load tests with a universal testing machine (M500-25AT, Testometric). After fracture occurred, the fracture force and elastic modulus were calculated. The data were analyzed by independent sample t test (α = .05) Results: There was no statistically significant difference between the two groups in terms of peak fracture force (P = .626) and elastic modulus (P = .125), and no catastrophic root fractures were observed in either group. CONCLUSIONS: The fracture resistance of endodontically treated teeth was not significantly influenced by the post material. 3D-printed, custom-made resin posts were as effective as fiber glass posts with regard to fracture resistance.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Resinas Compostas/química , Coroas , Vidro/química , Cimentos de Resina/química , Silicones , Impressão Tridimensional , Dente não Vital/terapia , Análise do Estresse Dentário
15.
Eur Radiol Exp ; 8(1): 36, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480588

RESUMO

BACKGROUND: Accurate assessment of breast implants is important for appropriate clinical management. We evaluated silicone properties and diagnostic accuracy for characterizing silicone implants and detecting degenerative changes including rupture in photon-counting computed tomography (PCCT). METHODS: Over 16 months, we prospectively included patients with silicone implants and available breast magnetic resonance imaging (MRI) who received thoracic PCCT performed in prone position. Consensus reading of all available imaging studies including MRI served as reference standard. Two readers evaluated all implants in PCCT reconstructions for degenerative changes. In a subgroup of implants, mean density of silicone, adjacent muscle, and fat were measured on PCCT reconstructions. Contrast-to-noise ratios (CNRs) were calculated for implant-to-muscle and implant-to-fat. RESULTS: Among 21 subjects, aged 60 ± 13.1 years (mean ± standard deviation) with 29 implants PCCT showed the following: high accuracy for linguine sign, intraimplant fluid (all > 0.99), peri-implant silicone (0.95), keyhole sign (0.90), and folds of the membrane (0.81); high specificity for linguine sign, intraimplant fluid, keyhole sign, folds of the membrane (all > 0.99), and peri-implant silicone (0.98); and high sensitivity for linguine sign and intraimplant fluid (all > 0.99). In a subgroup of 12 implants, the highest CNR for implant-to-muscle was observed on virtual unenhanced reconstructions (20.9) and iodine maps (22.9), for implant-to-fat on iodine maps (27.7) and monoenergetic reconstructions (31.8). CONCLUSIONS: Our findings demonstrate that silicone breast implants exhibit distinct contrast properties at PCCT, which may provide incremental information for detection of degenerative changes and rupture of implants. RELEVANCE STATEMENT: Thoracic photon-counting computed tomography is a promising modality for the diagnostic assessment of silicone breast implants. KEY POINTS: • Thoracic photon-counting computed tomography demonstrates unique contrast properties of silicone breast implants. • Iodine map reconstructions reveal strong contrast-to-noise ratios for implant-to-muscle and implant-to-fat. • Thoracic photon-counting computed tomography shows high diagnostic accuracy in detecting implant degeneration and rupture. TRIAL REGISTRATION: German Clinical Trials Register number DRKS00028997, date of registration 2022-08-08, retrospectively registered.


Assuntos
Implantes de Mama , Iodo , Humanos , Implantes de Mama/efeitos adversos , Projetos Piloto , Silicones , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Idoso , Feminino
16.
Int Ophthalmol ; 44(1): 136, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485796

RESUMO

BACKGROUND: The surface wettability of soft contact lenses (SCLs) affects the wearing comfort. Verofilcon A is a daily disposable silicone hydrogel contact lens with SMARTSURFACE® technology, ensuring high surface wettability. PURPOSE: To evaluate tear stability on the surface of verofilcon A and narafilcon A SCLs and correlate these findings with clinical parameters and patients' discomfort. METHODS: Sixty-two SCL wearers (124 eyes) with SCL discomfort were randomly assigned to use narafilcon A (control SCL) and verofilcon A for 2 weeks each by crossover. The noninvasive tear break-up time (NIBUT) of the naked eye at baseline and pre-lens NIBUT (PL-NIBUT) of the SCL surface after 2 weeks of using each SCL were measured using the DR-1α® dry eye observation device. Corneal superficial punctate keratopathy (SPK) (0-3) and conjunctival hyperemia (0-3), and comfort level of SCL wear (1-10) were also evaluated. RESULTS: NIBUT and PL-NIBUT values were 4.6 ± 2.3 s for the naked eye, 6.6 ± 6.6 s for narafilcon A, and 11.3 ± 3.5 s for verofilcon A. verofilcon A had significantly higher PL-NIBUT than the naked eye and narafilcon A (p < 0.05). SPK (0.16 ± 0.48 vs. 0.00 ± 0.00, p < 0.01) and conjunctival hyperemia (1.15 ± 0.82 vs. 0.49 ± 0.50, p < 0.01) scores were lower when wearing verofilcon A than narafilcon A. The ocular comfort score of wearing SCLs was higher with verofilcon A than with narafilcon A (8.7 ± 1.8 vs. 9.8 ± 0.5, p < 0.01). The ocular comfort score for wearing verofilcon A was higher, regardless of the baseline NIBUT. CONCLUSION: The results of this study showed a consistent surface-wetting advantage of verofilcon A in patients with ocular discomfort. verofilcon A was used comfortably in patients with low NIBUT scores at baseline. The findings suggest that verofilcon A is recommended for SCL wearers experiencing SCL-related dry eye symptoms and discomfort.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Hiperemia , Humanos , Hidrogéis , Silicones , Síndromes do Olho Seco/etiologia , Lágrimas
17.
Environ Sci Technol ; 58(12): 5229-5243, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38466915

RESUMO

Silicone-based passive samplers, commonly paired with gas chromatography-mass spectrometry (GC-MS) analysis, are increasingly utilized for personal exposure assessments. However, its compatibility with the biotic exposome remains underexplored. In this study, we introduce the wearable silicone-based AirPie passive sampler, coupled with nontargeted liquid chromatography with high-resolution tandem mass spectrometry (LC-HRMS/MS), GC-HRMS, and metagenomic shotgun sequencing methods, offering a comprehensive view of personalized airborne biotic and abiotic exposomes. We applied the AirPie samplers to 19 participants in a unique deep underwater confined environment, annotating 4,390 chemical and 2,955 microbial exposures, integrated with corresponding transcriptomic data. We observed significant shifts in environmental exposure and gene expression upon entering this unique environment. We noted increased exposure to pollutants, such as benzenoids, polycyclic aromatic hydrocarbons (PAHs), opportunistic pathogens, and associated antibiotic-resistance genes (ARGs). Transcriptomic analyses revealed the activation of neurodegenerative disease-related pathways, mostly related to chemical exposure, and the repression of immune-related pathways, linked to both biological and chemical exposures. In summary, we provided a comprehensive, longitudinal exposome map of the unique environment and underscored the intricate linkages between external exposures and human health. We believe that the AirPie sampler and associated analytical methods will have broad applications in exposome and precision medicine.


Assuntos
Expossoma , Doenças Neurodegenerativas , Hidrocarbonetos Policíclicos Aromáticos , Dispositivos Eletrônicos Vestíveis , Humanos , Espaços Confinados , Transcriptoma , Monitoramento Ambiental/métodos , Silicones
18.
Am J Dent ; 37(1): 53-56, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458984

RESUMO

PURPOSE: To evaluate flow profile and non-Newtonian behavior of 10 different silicone lining materials. METHODS: Ten commercially available silicone lining materials were selected for evaluation. The flow profile and non-Newtonian behavior of each material was measured using a shark fin testing method. Fin height and resultant base thickness were measured with a digital caliper and compared with one-way ANOVA and Student-Newman-Keuls post hoc test and fin base by Kruskal-Wallis one-way ANOVA on ranks with Dunn post hoc test with significance at P< 0.05 for both. RESULTS: Shark fin heights ranged from 9.62 ± 0.86 mm [Reline II (Soft)] to 25.54 ± 0.43 mm [Sofreliner (Medium)]. Shark fin bases ranged from 2.57 ± 0.51 mm [Sofreliner (Medium)] to 10.31 ± 0.57 mm [Reline II (Soft)]. Statistically significant differences were found between certain samples' shark fin heights as well as resultant bases (P< 0.05) indicating different rheological properties. CLINICAL SIGNIFICANCE: Silicone liner materials differ significantly with respect to flow profile and non-Newtonian behavior. While a high flow profile (low viscosity) of an elastomeric impression material improves accuracy, it may be a detriment to a denture lining material that must achieve a critical minimum thickness to provide resilience. Likewise, a low flow profile (high viscosity) material may also pose a disadvantage, requiring excessive compression and possible tissue distortion to achieve the same critical thickness. The results of this study should be considered when selecting the appropriate material for clinical application. Additional studies are indicated to further quantify rheological properties as well as correlate them to physical properties after the complete cure of the material.


Assuntos
Reembasadores de Dentadura , Silicones , Humanos , Viscosidade , Teste de Materiais , Bases de Dentadura , Elastômeros de Silicone , Propriedades de Superfície
19.
BMC Ophthalmol ; 24(1): 112, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454351

RESUMO

INTRODUCTION: Severe congenital ptosis poses a complex challenge for oculoplastic surgeons, requiring meticulous surgical intervention to restore eyelid function and improve aesthetic outcomes mainly by using frontalis sling approach. A crucial issue in frontalis sling surgeries is the sustainability of effect. PURPOSE: This retrospective study reports the outcomes of two surgical techniques for treating severe congenital ptosis in the paediatric age group: Silicon rods ptosis sling and a novel technique involving the use of Silicon rods with green braided polyester (Ethibond) sutures to secure the rods in place "sling for the sling". METHODS: The medical records of children who underwent frontalis suspension were reviewed in a retrospective fashion. We identified two groups; the first group (20 patients: 35 eyelids) had the traditional frontalis suspension surgery using silicone suspension set, the second group (14 patients: 25 eyelids) was operated using the new "sling for sling" technique. We used the postoperative marginal reflex distance-1 (MRD-1) as the primary outcome measure while the frequency of both wound related complications and recurrence were considered as secondary outcome measures. Post operative data were collected and compared after 1 month, 6 months, 12 months, and 18 months. RESULTS: Preliminary results indicate promising outcomes for both techniques, with significant improvement in eyelid elevation observed in both groups. However, the novel technique using Silicon rods with Ethibond sutures demonstrated enhanced sustainability, leading to a more durable outcome with significantly less recurrence. CONCLUSION: This study highlights the potential benefits of the novel technique in treating severe congenital ptosis and introduces an innovative approach to Silicone rods fixation to achieve a long-term corrective effect.


Assuntos
Blefaroplastia , Blefaroptose , Criança , Humanos , Blefaroplastia/métodos , Estudos Retrospectivos , Silício , Técnicas de Sutura , Blefaroptose/cirurgia , Blefaroptose/congênito , Silicones , Músculos Oculomotores/cirurgia , Resultado do Tratamento
20.
BMC Med Imaging ; 24(1): 53, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429683

RESUMO

BACKGROUND: The diameter of the ostial and proximal left main coronary artery can be greater than 5.0 mm. However, the diameters of the mostly available coronary drug-eluting stents (DESs) are ≤ 4.0 mm. Whether high-pressure dilatation can increase the diameter of stents from 4.0 to 5.0 mm and whether post-dilatation leads to longitudinal stent deformation (LSD) of 4.0-mm-diameter stents have rarely been studied. Therefore, this study aims to evaluate LSD and stent malapposition of six types of commercially available 4.0-mm-diameter stents in China in a 5.0-mm-diameter artificial blood vessel model by optical coherence tomography (OCT) in vitro. METHODS: The left main coronary artery was simulated by a truncated cone-shaped silicone tube. The internal diameters were 4.0 mm at one end of the silicone tube and 5.0 mm at the other end. Six different types of coronary stents widely used in China were selected for this study. Each stent was respectively implanted into the simulated blood vessel and dilated to a diameter of 4.2 mm according to the stent-balloon pressure compliance table. The stents were subjected to post-dilatation with a 5.0 × 15-mm noncompliant balloon. The LSD ratio of the longitudinal axis of each stent and stent malapposition were measured through OCT, and any fractures of the stents were determined. RESULTS: None of the six types of stents fractured following post-dilatation. The longitudinal axes of the BuMA and Excrossal stents were slightly shortened, while the other stents were elongated after high-pressure post-dilatation. All stents expanded to a diameter of 5.0 mm without incomplete stent apposition, except for the Nano Plus stent, which remained malapposed after high-pressure post-dilatation. CONCLUSION: All 4.0-mm-diameter stents can be expanded to a diameter of 5.0 mm by noncompliant balloon post-dilatation without stent strut fracture. Most stents were found to be well apposed after high-pressure post-dilatation. However, LSD was observed after post-balloon dilatation. Stent malapposition might be positively correlated with the percentage change in stent length.


Assuntos
Stents , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Dilatação , Stents/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...